1 YSTEM PECIFIER www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (
10 3.2 UNDERLAYMENT INSTALLATION A. Felt Underlayment: Install felt underlayment on roof sheathing under metal roof panels, unless otherw
11 3. Completed work shall be plumb and true, free of scrapes and dents. Panel ribs shall be on the module indicated in the contract drawi
2 1.4 PERFORMANCE REQUIREMENTS (Continued) B. PRODUCT PERFORMANCE 1. Struct
3 1.5 SUBMITTALS A. Product Data: Include construction details, material descriptions, dimensions of individual components and profiles,
4 1.6 QUALITY ASSURANCE (Continued) B. Testing Agency Qualifications: Qualified according to ASTM-E-329 for testing indicated, as docum
5 1.7 DELIVERY, STORAGE, AND HANDLING A. Delivery components, sheets, metal roof panels, and other manufactured items so as not to be damag
6 B. Special Warranty on Panel Finishes: Manufacturer’s standard from in which Manufacturer agrees to repair finish or replace metal roof pa
7 C. Panels shall be fabricated in full lengths from ridge to eave without end laps. Panels shall be 16” wide maximum with concealed anc
8 2.5 METAL SOFFIT PANELS A. General: Provide factory-formed metal soffit panels designed to be field assembled by lapping and interconne
9 E. Where indicated, fabricate metal roof panel joints with factory-installed captive gaskets or separator strips that provide a tight seal an