Englert S3000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pour la maison Englert S3000. Englert S3000 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
YSTEM
PECIFIER
www.englertinc.com
MANUFACTURER
ENGLERT, INC.
1200 Amboy Avenue
Perth Amboy, New Jersey 08861
Tel: (732) 826-8614
Fax: (732) 826-8865
SECTION 07411 - MANUFACTURED ROOF PANELS
This specification guide
is designed to assist in
the proper insertion of
Englert Roof Systems
into any architectural
building specifications.
This guide is formatted
to match the CSI Spec
Data System, however is
not part of that program.
PART I - GENERAL
SERIES 3000
1.1 RELATED DOCUMENTS
A. Drawings and general provision of the Contract, including General and Supplementary
Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes the following:
1. Site-formed or factory-formed roof panels.
2. Factory-formed and field-assembled, metal wall panels.
3. Metal soffit panels.
4. Roof accessories as noted.
B. Related Sections include the following:
1. Division 5 Section “Steel Deck” for steel roof deck supporting metal roof panels.
2. Division 5 Section “Cold-Formed Metal Framing” for secondary support framing
supporting metal roof panels.
3. Division 7 Section “Sheet Metal Flashing and Trim”.
4. Division 7 Section “Manufactured Roof Specialties” for assemblies that are not part
of metal roof panel assemblies.
5. Division 7 Section “Joint Sealants” for field-applied sealants not otherwise specified
in this Section.
1.3 DEFINITIONS
A. Metal Roof Assembly: Metal roof panels, attachment system components, miscellaneous
metal framing, thermal insulation, and accessories necessary for a
complete weathertight roofing system.
1.4 PERFORMANCE REQUIREMENTS
A. General: Provide metal roof panel assemblies that comply with performance requirements
specified as determined by testing a manufacturers’ standard assemblies similar to those
indicated for this Project, by a qualified testing and inspecting agency.
TRI\SPECS:3000:06/03/04
S
PECIFICATION
S
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - PECIFICATION

1 YSTEM PECIFIER www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (

Page 2

10 3.2 UNDERLAYMENT INSTALLATION A. Felt Underlayment: Install felt underlayment on roof sheathing under metal roof panels, unless otherw

Page 3

11 3. Completed work shall be plumb and true, free of scrapes and dents. Panel ribs shall be on the module indicated in the contract drawi

Page 4

2 1.4 PERFORMANCE REQUIREMENTS (Continued) B. PRODUCT PERFORMANCE 1. Struct

Page 5

3 1.5 SUBMITTALS A. Product Data: Include construction details, material descriptions, dimensions of individual components and profiles,

Page 6

4 1.6 QUALITY ASSURANCE (Continued) B. Testing Agency Qualifications: Qualified according to ASTM-E-329 for testing indicated, as docum

Page 7

5 1.7 DELIVERY, STORAGE, AND HANDLING A. Delivery components, sheets, metal roof panels, and other manufactured items so as not to be damag

Page 8

6 B. Special Warranty on Panel Finishes: Manufacturer’s standard from in which Manufacturer agrees to repair finish or replace metal roof pa

Page 9

7 C. Panels shall be fabricated in full lengths from ridge to eave without end laps. Panels shall be 16” wide maximum with concealed anc

Page 10

8 2.5 METAL SOFFIT PANELS A. General: Provide factory-formed metal soffit panels designed to be field assembled by lapping and interconne

Page 11

9 E. Where indicated, fabricate metal roof panel joints with factory-installed captive gaskets or separator strips that provide a tight seal an

Commentaires sur ces manuels